| Availability: | |
|---|---|
HV-2
HAIVOL
8535100000
The 11kV High Voltage Electrical Distribution Standard Fuse Cutout (Model HV-2) from HAIVOL is a industry-leading short-circuit protection and switching solution for 10kV to 38kV overhead power distribution systems. As a high-performance drop-out fuse cutout, it is engineered to deliver reliable overcurrent and short-circuit protection for distribution lines, distribution transformers and capacitor banks, while also serving as a flexible sectionalizing device for line maintenance and load management. Compatible with portable loadbreak tools, it functions as a dependable overhead line disconnect switch, meeting the rigorous operational demands of power system operators, electrical engineering contractors and grid infrastructure service providers. Manufactured in full compliance with global industry standards, this electrical distribution standard fuse cutout balances cost-effectiveness, ease of operation and exceptional adaptability to diverse outdoor operating environments.
Rated voltage(KV) | Rated current(A) | Rated interrupting current(KA) | Lightning impulse withstand voltage to ground (BIL KV) | Minimum power frequency withstand dry voltage to ground (KV) | Minimum creepage distance(mm) |
11-15 | 100/200 | 12 | 110 | 42 | 220 |
11-15 | 100/200 | 12 | 125 | 50 | 320 |
24-27 | 100/200 | 12 | 150 | 65 | 470 |
33-38 | 100/200 | 8 | 170 | 70 | 660 |
33-38 | 100/200 | 8 | 170 | 70 | 720 |
33-38 | 100/200 | 8 | 170 | 70 | 900 |
| | |
| | |
Our 11kV high voltage fuse cutout is built for long-term outdoor operation. For porcelain insulators, we use USA-made CGM INC por-rok anchoring cement for bonding, delivering rapid curing, high mechanical strength and superior weather aging resistance. For polymer insulators, one-piece injection molded high-temperature vulcanized silicone rubber ensures excellent sealing, tracking and erosion resistance. All ferrous components feature hot-dip galvanizing with a zinc coating exceeding 86μm, providing exceptional corrosion protection for harsh environments.
The single-vent design enables downward and outward exhaust during fault interruption, preventing rainwater intrusion, avoiding damage to upstream lines from discharged gas, and significantly improving interrupting capacity. An integrated arc-shortening copper rod further enhances short-circuit fault handling capability, ensuring reliable fault clearing without collateral equipment damage.
All copper cast components are made of high-grade bronze or brass, with silver-plated contact surfaces featuring a convex design to minimize contact resistance and maintain consistent conductivity. High-strength memory copper alloy sheets ensure seamless contact with the lower terminal, even during fuse element dropout, eliminating power interruptions and contact failure risks.
This standard fuse cutout is ideal for a wide range of power distribution scenarios, including primary side short-circuit protection for 10kV–38kV distribution transformers, overcurrent protection for overhead distribution line branch circuits, protection and switching control for capacitor banks, line sectionalizing for urban and rural grid maintenance, and backup protection for secondary distribution equipment in industrial parks.
We offer flexible customization to match your project requirements, with full support for bulk orders for grid upgrade projects and infrastructure developments. Customizable parameters include rated voltage and current, minimum creepage distance, insulator material, arc-shortening rod configuration and mounting bracket type. We maintain stable bulk inventory to ensure on-time delivery, with dedicated technical support for bulk order specification validation and project adaptation.
HAIVOL is a trusted manufacturer of high-voltage protection equipment, with all high voltage fuse cutouts manufactured and tested in strict accordance with IEC 60282-2:2008, IEEE Std C37.41-2008 and IEEE Std C37.42-2009 standards. We combine premium raw materials, precision manufacturing and rigorous full-inspection quality control to deliver products with a long service life and low maintenance costs. Our global technical support team provides end-to-end assistance, from product selection to after-sales service, ensuring seamless integration into your power distribution projects.
The HV-2 model is designed for 10kV to 38kV maximum design voltage, with standard configurations optimized for 11kV–15kV systems, plus extended options for 24kV–27kV and 33kV–38kV grids.
Yes, we offer both porcelain and polymer insulators for this model, allowing you to select the optimal material based on your operating environment, creepage distance requirements and project specifications.
Yes, when used with a compatible portable loadbreak tool, this fuse cutout can perform loadbreak operations, functioning as an overhead line disconnect switch for safe line maintenance and switching.
Beyond The Fuse Cutout: The 2026 Trend for Smart, Communicative, And Integrated Drop-out Fuse
Before You Buy: A Guide to Buying Zinc Oxide Surge Arresters
How to Select the Right Unscreened Separable Connector for Your Project
Load Break Switch vs Other Switch Types: Advantages and Differences
Become Familiar With Them: A Glossary of Terms Related to Expulsion Fuse Cutouts